MICHAEL, FAJRI SETIAWAN (2022) PERAWATAN POMPA PEMADAM GUNA MENUNJANG PENGOPERASIAN WATER CANON DI KAPAL PATROLI NEGARA 376 KSOP KHUSUS BATAM. KARYA TULIS.
Text
11. BAB 1 PENDAHULUAN.pdf Restricted to Repository staff only Download (47kB) |
|
Text
12. BAB 2 TINJUAN PUSTAKA.pdf Restricted to Repository staff only Download (331kB) |
Abstract
The Definition of Fire Pump A fire pump is a part of a fire sprinkler system's water supply and powered by electric, diesel or steam. The pump intake is either connected to the public underground water supply piping, or a static water source. The pump provides water flow at a higher pressure to the sprinkler system risers and hose standpipes. A fire pump is tested and listed for its use specifically for fire service by a third-party testing and listing agency. The fire pump starts when the pressure in the fire sprinkler system drops below a threshold. The sprinkler system pressure drops significantly when one or more fire sprinklers are exposed to heat above their design temperature, and opens, releasing water. Alternately, other fire hoses reels or other firefighting connections are opened, causing a pressure drop in the fire fighting main. The purpose of writing this paper is to determine the analysis of maintenance on the pump accompanied water canon if there is a problem with the pump when the ship is running or when the ship is on standby. Steps to be taken if a problem occurs in 2021 at the age of the ship which has entered its 5 th year after docking, what documents are needed when making repairs according to Standard Operation Procedures, the obstacles experienced and the methods used to overcome obstacles in the unloading process. Pump engine and maintenance of water canon on the ship For data collection used, the authors used methods obtained from type and data sources through interviews, observations which saw directly the activities on the ship, manuals, archives, and other sources. The results of this discussion can be concluded that KN.P-376 always performs routine maintenance on all machines on board the ship, especially the fire pump or Fire Pump accompanied water canon. Prioritize the smooth running of ships when conducting patrols in Batam waters and contribute to the security of the State of Indonesia. Although in the demolition activities there are still some problems that become obstacles in operation. Crew tried their best in an effort to carry out the process of repairing all machines, especially the fire pump or Fire Pump accompanied water canon to the maximum. Keywords : fire pump, water canon, standard operation procedure, fire, Patrol boat KN.P-376
Item Type: | Article |
---|---|
Additional Information: | 195720045 |
Subjects: | Teknika |
Divisions: | Program Studi > D3-Teknika |
Depositing User: | AMNI Perpustakaan Semarang |
Date Deposited: | 26 Apr 2022 03:54 |
Last Modified: | 26 Apr 2022 03:54 |
URI: | http://repository.unimar-amni.ac.id/id/eprint/4212 |
Actions (login required)
View Item |