ANALISIS SISTEM PENDINGIN AIR TAWAR MESIN INDUK DI MT. GAMSUNORO PT. PERTAMINA ( PERSERO )

HERMAWAN, HERMAWAN (2019) ANALISIS SISTEM PENDINGIN AIR TAWAR MESIN INDUK DI MT. GAMSUNORO PT. PERTAMINA ( PERSERO ). KARYA TULIS.

[img] Text
BAB I.pdf

Download (188kB)
[img] Text
BAB II.pdf

Download (205kB)

Abstract

Freshwater cooling system (closed system) is a cooling where fresh water is cooled seawater, then fresh water is circulated in the installation of the parent motorcycle cooling system, to absorb heat in lubricating oil, air rinse, cylinder wall, turbo charge, injector and valve exhaust gas. The heat contained in fresh water is reabsorbed by seawater through a tool called a cooler. Operation and maintenance of freshwater cooling systems include: operation of cooling systems, maintenance of central cooler filters, maintaining acid and base levels in cooling water. Treatment of the installation of freshwater cooling pipes. Maintenance of components that support the working of the freshwater cooling system on the host machine. The results of treatment on the freshwater cooling system on the parent machine on a regular basis, is expected to maintain the temperature in the freshwater cooling system to be stable in accordance with the specified. Keeping the cooling system supporting components durable and avoiding damage. Keywords : System, Cooling, Components.

Item Type: Article
Additional Information: 135120074
Subjects: Teknika
Divisions: Program Studi > D3-Teknika
Depositing User: AMNI Perpustakaan Semarang
Date Deposited: 06 Mar 2020 02:56
Last Modified: 06 Mar 2020 02:56
URI: http://repository.unimar-amni.ac.id/id/eprint/1966

Actions (login required)

View Item View Item